Raypak Variable-speed pump (RPVSP1, PS165VSP, PS270VSP) error codes

34 codes for PS270VSP, PS165VSP, RPVSP1: what each one means, what to check first, and when to call a pro.

Safety first

Pump: turn it off at the breaker before opening the drive or motor cover. Variable-speed drives can hold a dangerous charge for minutes after the power is off. Motor and drive wiring is for a qualified technician or electrician.

Jump to a code

CodeWhat it means
SW Over currentSoftware over current
HW Over currentHardware over current
DC Over voltageDC capacitor over voltage
DC Under voltageDC capacitor under voltage
PCB TemperaturePrinted circuit board over temperature
IGBT TemperatureInverter IGBT over temperature
Imbalance CurrentMotor current imbalance
Prime FailureFailure to Prime Pump
Startup FailureFailure to Start Pump
Low PowerLow power
Loss of PhaseLoss of phase
Processor FailureProcessor failure
POWERING DOWNPower down
Generic FaultAll other faults
Communication Error, Check ConnectionsThe user interface could not establish communication with the controller within five seconds
Over temperature faultMotor runs then stops because of an over-temperature fault
Over current faultMotor runs then stops because of an over-current fault
ER ---Communication error
Er ----- (power up)Self-diagnostic check at power up found an error
OCOvercurrent: the driver's output current is past the threshold (200% of rated current)
OVOvervoltage: the main circuit's maximum DC voltage is past the threshold
UVUnder-voltage: main electric current is low
OHOverheating (1.1kW): the motor heat sink is too hot
OC1Over current while adjusting speed
OC2Over current at steady speed
OV1Over voltage while decelerating
OC3Instantaneous over current
UV1Under voltage: main electric current has dropped too low
OC4Module over current
CECurrent transformer self inspection fault
OH1Overheat
FAULT LED SOLIDA fault occurred in the controller part of the electronics: an open motor phase, over/under voltage, over…
FAULT LED BLINKINGThe user interface has a fault
FAULT LEDThe unit has a fault error (quick start guide legend

SW Over current Software over current

Display shows: SW Over current (red Fault LED on)

What it means

Software over current. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

HW Over current Hardware over current

Display shows: HW Over current (red Fault LED on)

What it means

Hardware over current. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

DC Over voltage DC capacitor over voltage

Display shows: DC Over voltage (red Fault LED on)

What it means

DC capacitor over voltage. Controller action: Control waiting for voltage to drop.

What to check, in order

  1. Wait: control waiting for voltage to drop

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

DC Under voltage DC capacitor under voltage

Display shows: DC Under voltage (red Fault LED on)

What it means

DC capacitor under voltage. Controller action: Control waiting for voltage to rise.

What to check, in order

  1. Wait: control waiting for voltage to rise

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage or electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

PCB Temperature Printed circuit board over temperature

Display shows: PCB Temperature (red Fault LED on)

What it means

Printed circuit board over temperature. Controller action: Control waiting for temperature to drop.

What to check, in order

  1. Wait: control waiting for temperature to drop

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

IGBT Temperature Inverter IGBT over temperature

Display shows: IGBT Temperature (red Fault LED on)

What it means

Inverter IGBT over temperature. Controller action: Control waiting for temperature to drop.

What to check, in order

  1. Wait: control waiting for temperature to drop

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Imbalance Current Motor current imbalance

Display shows: Imbalance Current (red Fault LED on)

What it means

Motor current imbalance. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Prime Failure Failure to Prime Pump

Display shows: Prime Failure (red Fault LED on)

What it means

Failure to Prime Pump. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Ask Blue freeGive your techs Blue

Startup Failure Failure to Start Pump

Display shows: Startup Failure (red Fault LED on)

What it means

Failure to Start Pump. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Low Power Low power

Display shows: Low Power (red Fault LED on)

What it means

Low power. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Loss of Phase Loss of phase

Display shows: Loss of Phase (red Fault LED on)

What it means

Loss of phase. Controller action: Verify motor connected. Control will retry.

What to check, in order

  1. Verify the motor is connected
  2. Wait: the control will retry
  3. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Processor Failure Processor failure

Display shows: Processor Failure (red Fault LED on)

What it means

Processor failure. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

POWERING DOWN Power down

Display shows: POWERING DOWN (red Fault LED on)

What it means

Power down.

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Generic Fault All other faults

Display shows: Generic Fault (red Fault LED on)

What it means

All other faults. Controller action: Control will retry.

What to check, in order

  1. Wait: the control will retry
  2. If the motor does not restart after the retry, contact your service professional

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Communication Error, Check Connections The user interface could not establish communication with the controller within five seconds

What it means

The user interface could not establish communication with the controller within five seconds.

Common causes

What to check, in order

  1. Check the connections

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 27. maker's manual (PDF)

Over temperature fault Motor runs then stops because of an over-temperature fault

Display shows: Over temperature fault (Motor Runs then Stops)

What it means

Motor runs then stops because of an over-temperature fault.

Common causes

What to check, in order

  1. Make sure the back of the motor has no dirt or debris.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP, PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 28. maker's manual (PDF) The same code is also in 1 other manual or revision.

Over current fault Motor runs then stops because of an over-current fault

Display shows: Over current fault (Motor Runs then Stops)

What it means

Motor runs then stops because of an over-current fault; the motor restarts automatically after one minute.

What to check, in order

  1. Wait: the motor will automatically restart after one minute

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS270VSP, PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241509 Rev 1), page 28. maker's manual (PDF) The same code is also in 1 other manual or revision.

ER --- Communication error

Display shows: "ER ---" (communication error)

What it means

Communication error.

Common causes

What to check, in order

  1. Make sure the plug has good electrical contact
  2. Reset the system: unplug from the power supply, wait at least 60 seconds, reconnect
  3. If the error keeps coming back, contact your technical service.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.

Er ----- (power up) Self-diagnostic check at power up found an error

Display shows: "Er -----" at power up

What it means

Self-diagnostic check at power up found an error.

What to check, in order

  1. Have your installer or dealer fix the problem.

When to call a pro: The manufacturer's main advice for this code is to have a qualified service technician check the unit.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 11. maker's manual (PDF) The same code is also in 1 other manual or revision.

OC Overcurrent: the driver's output current is past the threshold (200% of rated current)

Display shows: "Er: OC"

What it means

Overcurrent: the driver's output current is past the threshold (200% of rated current). When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.

OV Overvoltage: the main circuit's maximum DC voltage is past the threshold

Display shows: "Er: OV"

What it means

Overvoltage: the main circuit's maximum DC voltage is past the threshold. When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.

UV Under-voltage: main electric current is low

Display shows: "Er: UV"

What it means

Under-voltage: main electric current is low. When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver. Fault no. 51 'UV' (under voltage) is when low speed voltage gets detected right after the pump is connected to power.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.

OH Overheating (1.1kW): the motor heat sink is too hot

Display shows: "Er: OH"

What it means

Overheating (1.1kW): the motor heat sink is too hot. When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 17. maker's manual (PDF) The same code is also in 1 other manual or revision.

OC1 Over current while adjusting speed

Display shows: "Er: OC1" (fault no. 0)

What it means

Over current while adjusting speed.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

OC2 Over current at steady speed

Display shows: "Er: OC2" (fault no. 1)

What it means

Over current at steady speed.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

OV1 Over voltage while decelerating

Display shows: "Er: OV1" (fault no. 2)

What it means

Over voltage while decelerating.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

OC3 Instantaneous over current

Display shows: "Er: OC3" (fault no. 4)

What it means

Instantaneous over current.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

UV1 Under voltage: main electric current has dropped too low

Display shows: "Er: UV1" (fault no. 5)

What it means

Under voltage: main electric current has dropped too low.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

OC4 Module over current

Display shows: "Er: OC4" (fault no. 6)

What it means

Module over current.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

CE Current transformer self inspection fault

Display shows: "Er: CE" (fault no. 17)

What it means

Current transformer self inspection fault.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving electrical parts (fuses, relays, transformers) is a job for a qualified technician.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

OH1 Overheat

Display shows: "Er: OH1" (fault no. 50)

What it means

Overheat.

Common causes

What to check, in order

  1. Press the START/STOP button to bring the controller back.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: RPVSP1
Source: the Raypak installation and operation manual (P/N 241832 Rev. 5), page 20. maker's manual (PDF)

FAULT LED SOLID A fault occurred in the controller part of the electronics: an open motor phase, over/under voltage, over…

Display shows: Fault LED solidly on

What it means

A fault occurred in the controller part of the electronics: an open motor phase, over/under voltage, over current, or over temperature. The motor stops and stays off, and the fault status is checked every seven seconds. When the fault clears, the Fault LED goes out and the motor returns to its normal schedule by itself (only STOP works during the fault).

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving measuring voltage is a job for a qualified technician.

Applies to: PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241508 Rev 1), page 28. maker's manual (PDF)

FAULT LED BLINKING The user interface has a fault

What it means

The user interface has a fault. The motor stops for as long as the fault lasts, then starts again by itself when it clears.

Common causes

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS165VSP
Source: the Raypak installation, operating and service manual (P/N 241508 Rev 1), page 28. maker's manual (PDF)

FAULT LED The unit has a fault error (quick start guide legend

Display shows: Fault LED lit

What it means

The unit has a fault error (quick start guide legend; see the PS165VSP owner's manual for solid/blinking meanings).

What to check, in order

The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.

When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.

Applies to: PS165VSP
Source: the Raypak quick start guide (Catalog No. 6200.182), page 1. maker's manual (PDF)

Blue knows every code and the manual for your exact model

Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.

Ask Blue free

Pool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.

Give your techs Blue

Questions

What does Raypak code Over temperature fault mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?

Motor runs then stops because of an over-temperature fault. First check: Make sure the back of the motor has no dirt or debris.

What does Raypak code Over current fault mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?

Motor runs then stops because of an over-current fault; the motor restarts automatically after one minute. First check: Wait: the motor will automatically restart after one minute.

What does Raypak code ER --- mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?

Communication error. First check: Make sure the plug has good electrical contact.

What does Raypak code Er ----- (power up) mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?

Self-diagnostic check at power up found an error. First check: Have your installer or dealer fix the problem.

What does Raypak code OC mean on Variable-speed pumps (RPVSP1, PS165VSP, PS270VSP)?

Overcurrent: the driver's output current is past the threshold (200% of rated current). When an overcurrent, overvoltage, undervoltage or overheating error occurs, the system recovers by itself (5 s of error details, then a 5 s countdown). Two errors within 60 seconds make the recovery time longer; after 3 such increases the pump drops into the ERROR menu and stops self-recovery, and pressing RUN there recovers the driver. First check: Press the START/STOP button to bring the controller back.

Related

General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.