Safety first
Heat pump: it uses high-voltage power and refrigerant under pressure. Turn the breaker off before opening a panel. Refrigerant, compressor and electrical repairs are for a qualified HVAC or pool technician.
Jump to a code
| Code | What it means |
|---|---|
| E1 | On/Off models: high pressure protection |
| E2 | On/Off models: low pressure protection |
| E3CROSSWIND-40-O through -65-O (Canada only) | On/Off models: low water pressure protection |
| E3CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: non-failure condition: No water protection |
| E4CROSSWIND-40-O through -65-O (Canada only) | On/Off models: on a single phase unit, a terminal at PROT2 on the PC board has a loose wire |
| E4CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: failure: 3 phase sequence protection (three phase only) |
| P1 | On/Off models: pool water temp sensor failure |
| P2CROSSWIND-40-O through -65-O (Canada only) | On/Off models: exhaust temp sensor failure |
| P2CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: failure: Water outlet temp sensor failure |
| P3CROSSWIND-40-O through -65-O (Canada only) | On/Off models: heating coil pipe temp sensor failure |
| P3CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: failure: Gas exhaust temp sensor failure |
| P4CROSSWIND-40-O through -65-O (Canada only) | On/Off models: gas return temp sensor failure |
| P4CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: failure: Evaporator coil pipe temp sensor failure |
| P5CROSSWIND-40-O through -65-O (Canada only) | On/Off models: air temp sensor failure |
| P5CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: failure: Gas return temp sensor failure |
| E6CROSSWIND-40-O through -65-O (Canada only) | On/Off models: compressor exhaust overload protection at 212°F (100°C) (heating models only) |
| E6CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models, not a failure: large temperature gap between inlet and outlet water (protection against… |
| P7CROSSWIND-40-O through -65-O (Canada only) | On/Off models: when air temp is under 32°F (0°C) the unit enters auto-stop protection, or anti-freeze, mode… |
| P7CROSSWIND-30-I, CROSSWIND-40-I … | Inverter models: failure: Ambient temp sensor failure |
| HEAT flashing | On/Off models: defrosting (not a failure) |
| E5 | Inverter models: non-failure condition: Power supply excesses operation range |
| Eb | Inverter models, not a failure: protection because ambient temperature is too high or too low |
| Ed | Inverter models: non-failure condition: Anti-freezing reminder |
| E7 | Inverter models, failure: protection because water outlet temp is too high or too low |
| E8 | Inverter models: failure: High exhaust temp protection |
| EA | Inverter models: failure: Evaporator overheat protection (only at cooling mode) |
| P0 | Inverter models: failure: Controller communication failure |
| P6 | Inverter models: failure: Cooling coil pipe temp sensor failure |
| P8 | Inverter models: failure: Cooling plate sensor failure |
| P9 | Inverter models: failure: Current sensor failure |
| PA | Inverter models: failure: Restart memory failure |
| F1 | Inverter models: failure: Compressor drive module failure |
| F2 | Inverter models: failure: PFC module failure |
| F3 | Inverter models: failure: Compressor start failure |
| F4 | Inverter models: failure: Compressor running failure |
| F5 | Inverter models: failure: Inverter board over current protection |
| F6 | Inverter models: failure: Inverter board overheat protection |
| F7 | Inverter models: failure: Current protection |
| F8 | Inverter models: failure: Cooling plate overheat protection |
| F9 | Inverter models: failure: Fan motor failure |
| Fb | Inverter models: failure: Power filter plate no-power protection |
| FA | Inverter models: failure: PFC module over current protection |
E1 On/Off models: high pressure protection
What it means
On/Off models: high pressure protection.
Common causes
- High pressure protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only), CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
E2 On/Off models: low pressure protection
What it means
On/Off models: low pressure protection.
Common causes
- Low pressure protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only), CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
E3 On/Off models: low water pressure protection
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: low water pressure protection.
Common causes
- Low water pressure protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
E3 Inverter models: non-failure condition: No water protection
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: non-failure condition: No water protection.
Common causes
- No water protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
E4 On/Off models: on a single phase unit, a terminal at PROT2 on the PC board has a loose wire
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: on a single phase unit, a terminal at PROT2 on the PC board has a loose wire; on a three phase unit, it is 3 phase sequence protection.
Common causes
- On a single phase unit, a terminal at PROT2 on the PC board has a loose wire. On a three phase unit, this is 3 phase sequence protection.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
E4 Inverter models: failure: 3 phase sequence protection (three phase only)
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: failure: 3 phase sequence protection (three phase only).
Common causes
- 3 phase sequence protection (three phase only)
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
P1 On/Off models: pool water temp sensor failure
What it means
On/Off models: pool water temp sensor failure.
Common causes
- Pool water temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only), CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P2 On/Off models: exhaust temp sensor failure
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: exhaust temp sensor failure; on heat and cooling models only, this refers to the cooling coil temp.
Common causes
- Exhaust temp sensor failure; on heat and cooling models only, this refers to the cooling coil temp.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
P2 Inverter models: failure: Water outlet temp sensor failure
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: failure: Water outlet temp sensor failure.
Common causes
- Water outlet temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P3 On/Off models: heating coil pipe temp sensor failure
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: heating coil pipe temp sensor failure.
Common causes
- Heating coil pipe temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
P3 Inverter models: failure: Gas exhaust temp sensor failure
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: failure: Gas exhaust temp sensor failure.
Common causes
- Gas exhaust temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P4 On/Off models: gas return temp sensor failure
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: gas return temp sensor failure.
Common causes
- Gas return temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
P4 Inverter models: failure: Evaporator coil pipe temp sensor failure
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: failure: Evaporator coil pipe temp sensor failure.
Common causes
- Evaporator coil pipe temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P5 On/Off models: air temp sensor failure
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: air temp sensor failure.
Common causes
- Air temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
P5 Inverter models: failure: Gas return temp sensor failure
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: failure: Gas return temp sensor failure.
Common causes
- Gas return temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
E6 On/Off models: compressor exhaust overload protection at 212°F (100°C) (heating models only)
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: compressor exhaust overload protection at 212°F (100°C) (heating models only).
Common causes
- Compressor exhaust overload protection at 212°F (100°C) (heating models only).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor or venting / flue is a job for a qualified technician.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
E6 Inverter models, not a failure: large temperature gap between inlet and outlet water (protection against…
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models, not a failure: large temperature gap between inlet and outlet water (protection against insufficient water flow).
Common causes
- Large temperature gap between inlet and outlet water (protection against insufficient water flow).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P7 On/Off models: when air temp is under 32°F (0°C) the unit enters auto-stop protection, or anti-freeze, mode…
On: CROSSWIND-40-O through -65-O (Canada only)
What it means
On/Off models: when air temp is under 32°F (0°C) the unit enters auto-stop protection, or anti-freeze, mode (not a failure).
Common causes
- When air temp is under 32°F (0°C) the unit enters auto-stop protection, or anti-freeze, mode (not a failure).
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
P7 Inverter models: failure: Ambient temp sensor failure
On: CROSSWIND-30-I, CROSSWIND-40-I …
What it means
Inverter models: failure: Ambient temp sensor failure.
Common causes
- Ambient temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
HEAT flashing On/Off models: defrosting (not a failure)
What it means
On/Off models: defrosting (not a failure).
Common causes
- Defrosting (not a failure)
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-40-O through -65-O (Canada only)
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 2 other manuals or revisions.
E5 Inverter models: non-failure condition: Power supply excesses operation range
What it means
Inverter models: non-failure condition: Power supply excesses operation range.
Common causes
- Power supply excesses operation range
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Eb Inverter models, not a failure: protection because ambient temperature is too high or too low
What it means
Inverter models, not a failure: protection because ambient temperature is too high or too low.
Common causes
- Protection triggered by ambient temperature that is too high or too low.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Ed Inverter models: non-failure condition: Anti-freezing reminder
What it means
Inverter models: non-failure condition: Anti-freezing reminder.
Common causes
- Anti-freezing reminder
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
E7 Inverter models, failure: protection because water outlet temp is too high or too low
What it means
Inverter models, failure: protection because water outlet temp is too high or too low.
Common causes
- Protection triggered by water outlet temp that is too high or too low.
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
E8 Inverter models: failure: High exhaust temp protection
What it means
Inverter models: failure: High exhaust temp protection.
Common causes
- High exhaust temp protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
EA Inverter models: failure: Evaporator overheat protection (only at cooling mode)
What it means
Inverter models: failure: Evaporator overheat protection (only at cooling mode).
Common causes
- Evaporator overheat protection (only at cooling mode)
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P0 Inverter models: failure: Controller communication failure
What it means
Inverter models: failure: Controller communication failure.
Common causes
- Controller communication failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P6 Inverter models: failure: Cooling coil pipe temp sensor failure
What it means
Inverter models: failure: Cooling coil pipe temp sensor failure.
Common causes
- Cooling coil pipe temp sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P8 Inverter models: failure: Cooling plate sensor failure
What it means
Inverter models: failure: Cooling plate sensor failure.
Common causes
- Cooling plate sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
P9 Inverter models: failure: Current sensor failure
What it means
Inverter models: failure: Current sensor failure.
Common causes
- Current sensor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
PA Inverter models: failure: Restart memory failure
What it means
Inverter models: failure: Restart memory failure.
Common causes
- Restart memory failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F1 Inverter models: failure: Compressor drive module failure
What it means
Inverter models: failure: Compressor drive module failure.
Common causes
- Compressor drive module failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F2 Inverter models: failure: PFC module failure
What it means
Inverter models: failure: PFC module failure.
Common causes
- PFC module failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F3 Inverter models: failure: Compressor start failure
What it means
Inverter models: failure: Compressor start failure.
Common causes
- Compressor start failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F4 Inverter models: failure: Compressor running failure
What it means
Inverter models: failure: Compressor running failure.
Common causes
- Compressor running failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the refrigerant system or compressor is a job for a qualified technician.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F5 Inverter models: failure: Inverter board over current protection
What it means
Inverter models: failure: Inverter board over current protection.
Common causes
- Inverter board over current protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F6 Inverter models: failure: Inverter board overheat protection
What it means
Inverter models: failure: Inverter board overheat protection.
Common causes
- Inverter board overheat protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F7 Inverter models: failure: Current protection
What it means
Inverter models: failure: Current protection.
Common causes
- Current protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F8 Inverter models: failure: Cooling plate overheat protection
What it means
Inverter models: failure: Cooling plate overheat protection.
Common causes
- Cooling plate overheat protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
F9 Inverter models: failure: Fan motor failure
What it means
Inverter models: failure: Fan motor failure.
Common causes
- Fan motor failure
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Fb Inverter models: failure: Power filter plate no-power protection
What it means
Inverter models: failure: Power filter plate no-power protection.
Common causes
- Power filter plate no-power protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
FA Inverter models: failure: PFC module over current protection
What it means
Inverter models: failure: PFC module over current protection.
Common causes
- PFC module over current protection
What to check, in order
The manufacturer lists no fix steps for this message; it reports a state of the equipment. If it does not clear by itself, see when to call a pro below.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CROSSWIND-30-I, CROSSWIND-40-I, CROSSWIND-50-I, CROSSWIND-65-I
Source: the Raypak installation and operation manual (P/N 241827 Rev. 3), page 26. maker's manual (PDF) The same code is also in 3 other manuals or revisions.
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Raypak code E1 mean on Crosswind heat pumps?
On/Off models: high pressure protection.
What does Raypak code E2 mean on Crosswind heat pumps?
On/Off models: low pressure protection.
What does Raypak code E3 mean on Crosswind heat pumps?
Inverter models: non-failure condition: No water protection.
What does Raypak code P1 mean on Crosswind heat pumps?
On/Off models: pool water temp sensor failure.
What does Raypak code P2 mean on Crosswind heat pumps?
Inverter models: failure: Water outlet temp sensor failure.
Related
- Raypak Crosswind V heat pumps (TWPH 4550–8550)
- Raypak Side-discharge heat pumps (TWPH-H50HC–H90HC)
- Raypak Heat pumps 2450–8450HC
- Raypak Heat pumps 2350–8350HC (Raypak & Rheem)
- Raypak Heat pumps 5300, 6300 & 8300
- Raypak Professional Series heat pumps (9350HC–10355HC)
- All Raypak error codes
- All pool equipment error codes
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.