Safety first
Gas heater: the gas valve, burners, ignition, flame sensing, venting and anything behind the cabinet panels are for a qualified gas technician. Never jumper or bypass a safety switch or limit. If you smell gas, shut off the gas supply, do not touch electrical switches, leave the area and call your gas company from outside.
Jump to a code
| Code | What it means |
|---|---|
| Gas Pressure SW | Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset… |
| Flow Switch/ LWCO | The flow switch or optional low water cutoff is not making |
| Flame Sequence | Flame signal seen while the gas valve is de-energized |
| Anti-cycling | Call for heat received too soon after the previous one ended |
| No Flame Ign | Burner flame not proven on ignition |
| HSI Current Low | Hot surface igniter draw below the 2.6 A minimum |
| Flame CKT Error | Main control board internal fault |
| No Flame Running | Flame signal lost while running |
| Auto Reset High Limit | Outlet water temperature exceeded the automatic reset high limit setting |
| Manual Reset High Limit | Outlet water temperature exceeded the adjustable high limit setting |
| Inlet Low | Inlet water failed to pass 130° within 15 minutes after ignition |
| Sensor Open | Inlet, outlet, system supply, system return or outdoor sensor disconnected |
| Sensor Shorted | Inlet, outlet, system supply, system return or outdoor sensor shorted |
| Louver Proving | Optional remote proving switch is not making |
| APS Open | The combustion air blower started, but the air pressure switch had not closed after 1 minute |
| APS Closed | Air pressure switch closed before the combustion air blower started |
| Wrong ID Plug | The control module ID plug does not agree with parameter L5 (the repair steps mention parameter I5) |
| Temp O/Shoot | Two conditions: temperature rise across the heat exchanger above the set parameters, or outlet water above… |
| Rem Ctrl Flt | External control is cycling too often |
| Parameters Progr | Parameters were loaded from a laptop, so the main control board needs a reset |
| Service Blk | In Service Mode the outlet temperature exceeded 185°F (85°C) |
| Low Voltage | 120VAC input to the main control board dropped below 100VAC |
| Watch Dog Error | Main control board internal fault |
| Write EEProm | Main control board internal fault |
| Program EEProm | Main control board internal fault |
| CRC Parameters | Main control board internal fault |
| No Error Stored | Main control board internal fault |
Gas Pressure SW Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset…
What it means
Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset low gas switch open). Manual reset needed after correction (RESET on the CXi display).
Common causes
- Low or high gas pressure switch tripped
What to check, in order
- Reset the pressure switches
- Measure supply gas pressure to find the cause
- Correct supply gas pressure if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving gas supply and pressure is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)
Flow Switch/ LWCO The flow switch or optional low water cutoff is not making
What it means
The flow switch or optional low water cutoff is not making. Lockout resets automatically after 5 minutes, or press RESET once corrected.
Common causes
- Flow switch or low water cutoff not made
What to check, in order
- On a call for heat, see whether the pump runs.
- Look for closed valves or blockages in the piping.
- Make sure the system is full of water and every bit of air has been purged.
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)
Flame Sequence Flame signal seen while the gas valve is de-energized
What it means
Flame signal seen while the gas valve is de-energized. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Flame signal with gas valve off
What to check, in order
- Check supply voltage polarity
- Check that the gas valve is closed
- Check external wiring for voltage feedback
- Check internal wiring for bad connections
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)
Anti-cycling Call for heat received too soon after the previous one ended
What it means
Call for heat received too soon after the previous one ended.
Common causes
- Call for heat too soon after the last one
What to check, in order
- None needed: the board releases the call after a set time, or if the outlet temperature drops too quickly
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 29. maker's manual (PDF)
No Flame Ign Burner flame not proven on ignition
What it means
Burner flame not proven on ignition. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Failed to prove flame on ignition
What to check, in order
- Examine the igniter and its wiring; clean or replace them.
- Check unit grounding
- Check incoming gas pressure
- Check the gas valve-to-combustion air chamber tube
- Check vent/air intake pipes for correct installation and obstructions
- Examine the burners; clean or replace them.
- Test the manifold gas pressure and the combustion settings.
- Check 24VAC to the gas valve during ignition; if missing check wiring to the main control board
- Replace wiring or the main control board as needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 30. maker's manual (PDF)
HSI Current Low Hot surface igniter draw below the 2.6 A minimum
What it means
Hot surface igniter draw below the 2.6 A minimum. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Hot surface igniter amp draw below 2.6 A
What to check, in order
- Measure igniter amps during trial for ignition: below 2.6 A replace the igniter
- Above 2.6 A replace the control module
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 30. maker's manual (PDF)
Flame CKT Error Main control board internal fault
What it means
Main control board internal fault.
Common causes
- Main control board internal fault
What to check, in order
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 30. maker's manual (PDF)
No Flame Running Flame signal lost while running
What it means
Flame signal lost while running. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Flame lost while running
What to check, in order
- Inspect igniter and wiring; clean or replace
- Check unit grounding
- Check incoming gas pressure
- Check the gas valve-to-combustion air chamber tube
- Check vent/air intake pipes
- Test the manifold gas pressure and combustion.
- Inspect, clean or replace burners
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the gas valve, burners, the igniter or ignition control or control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 31. maker's manual (PDF)
Auto Reset High Limit Outlet water temperature exceeded the automatic reset high limit setting
What it means
Outlet water temperature exceeded the automatic reset high limit setting.
Common causes
- Outlet water above the auto reset high limit
- Air in system or low water
- Incorrect piping
- Pump not running
- Variable speed pump flow below heater flow
- Faulty water sensor
What to check, in order
- Make sure the system is full of water and every bit of air has been purged.
- Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
- On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
- If 120VAC is present and the pump does not run, replace the pump
- With a variable speed pump, make sure system flow is not less than heater flow
- Check the board temperature setting
- Compare the water sensor resistance with the specified values; replace the sensor if needed.
- Replace the outlet sensor
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 31. maker's manual (PDF)
Manual Reset High Limit Outlet water temperature exceeded the adjustable high limit setting
What it means
Outlet water temperature exceeded the adjustable high limit setting. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Outlet water above the adjustable high limit
- Air in system or low water
- Incorrect piping
- Pump not running
- Variable speed pump flow below heater flow
- Faulty water sensor
What to check, in order
- Verify the adjustable high limit setting
- Make sure the system is full of water and every bit of air has been purged.
- Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
- On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
- If 120VAC is present and the pump does not run, replace the pump
- With a variable speed pump, make sure system flow is not less than heater flow
- Check the board temperature setting
- Compare the water sensor's resistance with the specified values and replace it if needed.
- Replace the outlet sensor or high limit
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)
Inlet Low Inlet water failed to pass 130° within 15 minutes after ignition
What it means
Inlet water failed to pass 130° within 15 minutes after ignition.
Common causes
- 3-way valve wiring or valve fault
- Faulty inlet sensor
- Faulty main control board
What to check, in order
- Inspect the wiring that runs from the low voltage connection board to the 3-way valve.
- After the heater fires, look for 24VAC across Close and COM at the 3-way valve. If 24VAC is there but the valve stays still, replace it.
- Replace the inlet sensor
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving the igniter or ignition control, control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)
Sensor Open Inlet, outlet, system supply, system return or outdoor sensor disconnected
What it means
Inlet, outlet, system supply, system return or outdoor sensor disconnected. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Temperature sensor disconnected
What to check, in order
- Check sensors and wiring; repair or replace
- Compare the sensor resistance with the specified values.
- Replace the sensor if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)
Sensor Shorted Inlet, outlet, system supply, system return or outdoor sensor shorted
What it means
Inlet, outlet, system supply, system return or outdoor sensor shorted. Manual reset needed after correction (RESET on the CXi display).
Common causes
- Temperature sensor shorted
What to check, in order
- Check sensors and wiring; repair or replace
- Compare the sensor resistance with the specified values.
- Replace the sensor if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 32. maker's manual (PDF)
Louver Proving Optional remote proving switch is not making
What it means
Optional remote proving switch is not making. Lockout resets automatically after 5 minutes, or press RESET once corrected.
Common causes
- Remote proving switch open
- Loose or missing jumper when no proving switch is installed
What to check, in order
- Check remote devices
- Check for a loose or misplaced jumper if no proving switch is installed
When to call a pro: If these checks do not clear it, or the code keeps coming back, have a pool technician look at the equipment.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)
APS Open The combustion air blower started, but the air pressure switch had not closed after 1 minute
What it means
The combustion air blower started, but the air pressure switch had not closed after 1 minute. The lockout clears itself after 5 minutes, or press RESET after the fix.
Common causes
- Dirty air filter
- Vent/air intake too long
- Blocked vent or air inlet
- Combustion air blower not running
What to check, in order
- Clean or replace the air filter
- Vent/air intake lengths must not exceed the maximum
- Clear blockage in vent/air inlet pipe or terminations
- Check the combustion air blower; replace if needed
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)
APS Closed Air pressure switch closed before the combustion air blower started
What it means
Air pressure switch closed before the combustion air blower started. Lockout resets automatically after 5 minutes, or press RESET once corrected.
Common causes
- Jumper on the air pressure switch
- Vent stack has an unusually strong negative draft.
What to check, in order
- Check for a jumper on the air pressure switch
- Look for an unusually strong negative draft in the vent stack.
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving venting / flue is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)
Wrong ID Plug The control module ID plug does not agree with parameter L5 (the repair steps mention parameter I5)
What it means
The control module ID plug does not agree with parameter L5 (the repair steps mention parameter I5).
Common causes
- ID plug not connected or damaged
- Control module does not match the panel label
What to check, in order
- Check the ID plug on connector X5
- Check ID plug wiring and connectors
- Confirm the number on the panel label equals parameter I5; if it does not, replace the control module.
- When replacing a module, confirm I5 matches the label, then press ENTER; otherwise replace the module
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 33. maker's manual (PDF)
Temp O/Shoot Two conditions: temperature rise across the heat exchanger above the set parameters, or outlet water above…
What it means
Two conditions: temperature rise across the heat exchanger above the set parameters, or outlet water above the maximum outlet temperature. Lockout resets automatically after 5 minutes, or press RESET once corrected.
Common causes
- Heat exchanger temperature rise too high
- Outlet water above maximum
- Air in system or low water
- Incorrect piping
- Pump not running
What to check, in order
- Make sure the system is full of water and every bit of air has been purged.
- Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
- On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
- If 120VAC is present and the pump does not run, replace the pump
- Outlet over maximum: replace the main control board if the above check out
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 34. maker's manual (PDF)
Rem Ctrl Flt External control is cycling too often
What it means
External control is cycling too often.
Common causes
- External control cycling too often
What to check, in order
- Check the external control set point
- Check the wires that run from the outside controller to the unit.
- Replace the control
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 34. maker's manual (PDF)
Parameters Progr Parameters were loaded from a laptop, so the main control board needs a reset
What it means
Parameters were loaded from a laptop, so the main control board needs a reset. After the correction, reset it by hand (RESET on the CXi display).
Common causes
- Parameters downloaded
What to check, in order
- Press ENTER/RESET on the CXi display
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 34. maker's manual (PDF)
Service Blk In Service Mode the outlet temperature exceeded 185°F (85°C)
What it means
In Service Mode the outlet temperature exceeded 185°F (85°C).
Common causes
- No heating load in Service Mode
- Air in system or low water
- Incorrect piping
- Pump not running
What to check, in order
- Create a heating load to remove heat
- Make sure the system is full of water and every bit of air has been purged.
- Verify the heater is piped correctly (Water Connections section of the Installation & Operation Manual)
- On a call for heat, confirm 120VAC reaches the pump motor. If it is missing, check the wiring that leads to the main control board, and replace that board if needed.
- If 120VAC is present and the pump does not run, replace the pump
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage or wiring is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
Low Voltage 120VAC input to the main control board dropped below 100VAC
What it means
120VAC input to the main control board dropped below 100VAC.
Common causes
- Low supply voltage
- Loose low voltage wiring
- Wire too small or too long to remote devices
What to check, in order
- Check 120VAC supply to the transformer
- Check connections at the low voltage terminal strip
- Check wire size/length to remote devices
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards, measuring voltage, wiring or electrical parts (fuses, relays, transformers) is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
Watch Dog Error Main control board internal fault
What it means
Main control board internal fault.
Common causes
- Main control board internal fault
What to check, in order
- Cycle main power
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
Write EEProm Main control board internal fault
What it means
Main control board internal fault.
Common causes
- Main control board internal fault
What to check, in order
- Cycle main power
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
Program EEProm Main control board internal fault
What it means
Main control board internal fault.
Common causes
- Main control board internal fault
What to check, in order
- Cycle main power
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
CRC Parameters Main control board internal fault
What it means
Main control board internal fault.
Common causes
- Main control board internal fault
What to check, in order
- Cycle main power
- Replace the main control board
- Restore default parameters with the PC program
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
No Error Stored Main control board internal fault
What it means
Main control board internal fault.
Common causes
- Main control board internal fault
What to check, in order
- Press RESET
- Cycle main power
- Replace the main control board
When to call a pro: Simple checks (power, water flow, filter, valves and settings) are fine to do yourself. Anything involving control boards is a job for a qualified technician.
Applies to: CXi 500, CXi 650, CXi 750
Source: the Jandy service manual (100324298_2000579556 Rev A), page 35. maker's manual (PDF)
Blue knows every code and the manual for your exact model
Ask Blue free in the Pool AI app: tell Blue the code and your model, and get the steps for your equipment.
Ask Blue freePool company? Give your techs Blue: every code, every manual and your customers' equipment in one app.
Questions
What does Jandy code Gas Pressure SW mean on CXi commercial heaters?
Optional manual-reset low or high gas pressure switch tripped (models 992-2072 natural gas: automatic-reset low gas switch open). Manual reset needed after correction (RESET on the CXi display). First check: Reset the pressure switches.
What does Jandy code Flow Switch/ LWCO mean on CXi commercial heaters?
The flow switch or optional low water cutoff is not making. Lockout resets automatically after 5 minutes, or press RESET once corrected. First check: On a call for heat, see whether the pump runs.
What does Jandy code Flame Sequence mean on CXi commercial heaters?
Flame signal seen while the gas valve is de-energized. Manual reset needed after correction (RESET on the CXi display). First check: Check supply voltage polarity.
What does Jandy code Anti-cycling mean on CXi commercial heaters?
Call for heat received too soon after the previous one ended. First check: None needed: the board releases the call after a set time, or if the outlet temperature drops too quickly.
What does Jandy code No Flame Ign mean on CXi commercial heaters?
Burner flame not proven on ignition. Manual reset needed after correction (RESET on the CXi display). First check: Examine the igniter and its wiring; clean or replace them.
Related
- Jandy JXiQ heaters
- Jandy JXi heaters
- Jandy LXi heaters
- Jandy Legacy LRZ heaters
- Jandy Lite2 LJ heaters
- All Jandy error codes
- All pool equipment error codes
General information from the manufacturers' manuals, written in our own words. Pool AI is not affiliated with or endorsed by the brands named here; brand and model names belong to their owners. Always follow the manual for your exact model and your local codes. Work on gas, high voltage and refrigerant only by qualified, licensed people. Updated 2026-11-23.